Southwire® Romex® SIMpull® 63950021 Type NM-B Sheathed Cable With Ground Wire, Coil Packaging, 600 V, (3) 6 AWG Stranded Copper Conductor, 25 ft L, Black
Southwire® Romex® Brand SIMpull ® NM-B (nonmetallic-sheathed) cable may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90C (with ampacity limited to that for 60C conductors) as specified in the National Electrical Code. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B cable is 600 volts.
-
BrandSouthwire®
-
UPC032886263736
-
Manufacturer Part Number63950021
-
CountryUSA
-
Temperature Rating90 deg C
-
TypeType NM-B
-
Conductor Size6 AWG
-
Conductor TypeStranded Copper
-
Voltage Rating600 V
-
Amperage Rating55 A
-
Number of Conductors3
-
Insulation Material30 mil PVC
-
Jacket ColorBlack
-
Jacket Material30 mil Nylon
-
Strands7
-
Outside Diameter658 mil
-
Length25 ft
- Southwire Romex Brand SIMpull NM-B (nonmetallic-sheathed) cable may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90C
- NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations
- Voltage rating for NM-B cable is 600 V
-
Alternative Part Number16733581
-
UNSPSC26121517
-
IDEA Index ID16733581
-
Standards/ApprovalsASTM B3/B8|Federal Specification A-A-59544|Green Specification|National Electrical Code NFPA 70|REACH Compliant|RoHS Compliant|UL 83/719
-
Warranty1 Year
-
Specification Sheet
Recently Viewed
Southwire® Romex® SIMpull® 63950021 Type NM-B Sheathed Cable With Ground Wire, Coil Packaging, 600 V, (3) 6 AWG Stranded Copper Conductor, 25 ft L, Black
Southwire® Romex® Brand SIMpull ® NM-B (nonmetallic-sheathed) cable may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90C (with ampacity limited to that for 60C conductors) as specified in the National Electrical Code. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches, and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B cable is 600 volts.
3.250" X 4.249" X .250" SMALL BORE RADIAL SHAFT SEAL. NITRILE LIP, BORE TITE COATING
22-MM STUD TYPE CAM FOLLOWERS-INAKR22PP>
Bondhus® 10912 Ball End Hex Key, L-Handle Handle, Protanium® High Torque Steel, ProGuard™
Bondhus® 10912 Ball End Hex Key, L-Handle Handle, Protanium® High Torque Steel, ProGuard™
Conductor Range: 6 AWG to 250 kcmil (MCM) stranded copper wires. Stud/Bolt Size: 3/8-inch mounting hole. Drive Size: 1/4-inch internal hex main drive screw. Voltage & Temperature: Rated for up to 35 kV (with proper high-voltage insulation spacing techniques) and a maximum temperature of 90°C.Pre-Filled Compound: Contains DE-OX® oxide inhibitor to protect contact surfaces from corrosion. Certifications: UL 467 Listed (Grounding and Bonding), UL 486A/B Listed, and CS
1.181" X 2.047" X .315" OIL SEAL-CHI11640 >