ILSCO® ClearChoice® IK-750 Type IK Split Bolt Connector, 350 to 750 kcmil, 8 AWG Compact/Compressed/Concentric/Solid Copper Conductor, 1.938 x 3.75 in, Copper Alloy
ILSCO® ClearChoice® IK-750 Type IK Split Bolt Connector, 350 to 750 kcmil, 8 AWG Compact/Compressed/Concentric/Solid Copper Conductor, 1.938 x 3.75 in, Copper Alloy
-
BrandILSCO®
-
UPC783669470246
-
Manufacturer Part NumberIK-750
-
CountryUSA
-
Temperature Rating90 deg C
-
MaterialCopper Alloy
-
TypeType IK
-
Conductor Size350 to 750 kcmil, 8 AWG
-
Conductor TypeCompact/Compressed/Concentric/Solid Copper
-
Voltage Rating2000 V AC
-
Dimensions2-1/8 in H x 3-3/4 in W
-
Specifications1.03 in Split, 2-1/8 in Hex Nut, 1000 in-lb Recommended Torque
-
Bolt Size1.938 x 3.75 in
- Manufactured from high strength copper alloy provides maximum conductivity and high breakage resistance
- Precision tooled threads allows maximum torque to be applied
- For use with copper conductor types solid, compact, compressed, concentric
- Suitable for direct burial in earth and concrete
- Application versatility
- Allows maximum torque to be applied
-
Alternative Part Number7771272
-
UNSPSC39121408
-
IDEA Index ID7771272
-
Package DescriptionEACH
-
Standards/ApprovalsCSA Certified|RUS Certified|UL 467|PROP65: Cancer and Reproductive Harm - www.P65warnings.ca.gov
-
Specification Sheet
-
Specification Sheet
Recently Viewed
ILSCO® ClearChoice® IK-750 Type IK Split Bolt Connector, 350 to 750 kcmil, 8 AWG Compact/Compressed/Concentric/Solid Copper Conductor, 1.938 x 3.75 in, Copper Alloy
ILSCO® ClearChoice® IK-750 Type IK Split Bolt Connector, 350 to 750 kcmil, 8 AWG Compact/Compressed/Concentric/Solid Copper Conductor, 1.938 x 3.75 in, Copper Alloy
RIDGID® Rapidgrip® 12693 Pipe Wrench, 2 in Pipe, 14 in OAL, Spring-Loaded Jaw, Aluminum Handle, Knurled Nut Adjustment
RIDGID® Rapidgrip® 12693 Pipe Wrench, 2 in Pipe, 14 in OAL, Spring-Loaded Jaw, Aluminum Handle, Knurled Nut Adjustment
Edison's Class T current-limiting, fast-acting fuses. Provides 10X better current limitation to help prevent equipment damage caused by short-circuit events. 200 kA Interrupting rating complies with NEC Section 110.9 for today’s large capacity systems. Small, space-saving fuses provide a high degree of current limitation on short-circuits for excellent component protection.
Edison's Class T current-limiting, fast-acting fuses. Provides 10X better current limitation to help prevent equipment damage caused by short-circuit events. 200 kA Interrupting rating complies with NEC Section 110.9 for today’s large capacity systems. Small, space-saving fuses provide a high degree of current limitation on short-circuits for excellent component protection.
Edison's Class T current-limiting, fast-acting fuses. Provides 10X better current limitation to help prevent equipment damage caused by short-circuit events. 200 kA Interrupting rating complies with NEC Section 110.9 for today’s large capacity systems. Small, space-saving fuses provide a high degree of current limitation on short-circuits for excellent component protection.
Edison's Class T current-limiting, fast-acting fuses. Provides 10X better current limitation to help prevent equipment damage caused by short-circuit events. 200 kA Interrupting rating complies with NEC Section 110.9 for today’s large capacity systems. Small, space-saving fuses provide a high degree of current limitation on short-circuits for excellent component protection.