Eaton
EATON CHB240 Type CHB Standard Molded Case Circuit Breaker, 120/240 V AC, 40 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHB260 Type CHB Standard Molded Case Circuit Breaker, 120/240 V AC, 60 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHB340 Type CHB Standard Molded Case Circuit Breaker, 240 V AC, 40 A, 10 kA Interrupt, 3 Poles, Thermal Magnetic Trip
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHF115 Type CHF Standard Circuit Breaker With Mechanical Trip Flag, 120/240 V AC, 15 A, 10 kA Interrupt, 1 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHF120 CH Series Type CHF Standard Thermal Magnetic Circuit Breaker, 120/240 V AC, 20 A, 10 kA Interrupt, 1 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHF125 Type CHF Standard Circuit Breaker With Mechanical Trip Flag, 120/240 V AC, 25 A, 10 kA Interrupt, 1 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHF130 Standard Circuit Breaker With Mechanical Trip Flag, 120/240 V AC, 30 A, 10 kA Interrupt, 1 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHF215 Type CHF Standard Circuit Breaker With Mechanical Trip Flag, 120/240 V AC, 15 A, 10 kA Interrupt, 2 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHF220 Type CHF Standard Circuit Breaker With Mechanical Trip Flag, 120/240 V AC, 20 A, 10 kA Interrupt, 2 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHF230 Type CHF Standard Circuit Breaker With Mechanical Trip Flag, 120/240 V AC, 30 A, 10 kA Interrupt, 2 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHF235 Type CHF Standard Thermal Magnetic Circuit Breaker With Mechanical Trip Flag, 120/240 V AC, 35 A, 10 kAIC Interrupt, 2 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHF240 Type CHF Standard Thermal Magnetic Circuit Breaker With Mechanical Trip Flag, 120/240 V AC, 40 A, 10 kAIC Interrupt, 2 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHF245 Type CHF Circuit Breaker, 120/240 V AC, 45 A, 10 kA Interrupt, 2 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHF250 Type CHF Standard Thermal Magnetic Circuit Breaker With Mechanical Trip Flag, 120/240 V AC, 50 A, 10 kAIC Interrupt, 2 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHFCAF115 Type CH Combination Standard Arc Fault Circuit Breaker, 120/240 V AC, 15 A, 10 kA Interrupt, 1 Poles, Thermal Magnetic Trip
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHFCAF120 Type CH Branch Feeder Combination AFCI Circuit Breaker, 120/240 VAC, 20 A, 10 kA Interrupt, 1 Poles
EATON CH ground fault current interrupters (GFCIs) are 3/4 in W and provide superior safety over a standard electrical outlet in areas where electricity may come into contact with water. GFCIs are required in any application near water such as kitchen countertops, bathrooms, swimming pools, hot tubs and outdoor receptacles. They immediately break the circuit when electrical current leakage is detected, reducing the risk of shock and electrocution.
EATON CHFGFT130 CH Series GFCI Circuit Breaker With Flag, 120 V, 30 A, 10 kA Interrupt, 1 Poles, Thermal Magnetic Trip
EATON residential CH circuit breakers provide premium overload protection. The type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHFN115DF Type CH Dual Function Arc Fault/Ground Fault Combination Circuit Breaker, 120/240 V AC, 15 A, 10 kA Interrupt, 1 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHFN120GF Type CH Self-Test Ground Fault Circuit Breaker, 120/240 V AC, 20 A, 10 kA Interrupt, 1 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHFP Filler Plate, 3-1/2 in L x 3/4 in W, For Use With Type CH 3/4 in Loadcenter
Eaton’s CH 3/4-inch loadcenters enclose CH circuit breakers for power distribution and circuit protection in residential and light commercial applications. Also called a breaker box, electrical box or even a fuse box, the main function is to take electricity supplied by the utility and distribute it throughout the home to feed lights and receptacles. Covers are typically packaged separately and available as surface or flush mount.
EATON CHT2020 Type CHT Twin Circuit Breaker, 120/240 V AC, 20 A, 10 kA Interrupt, 1 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHU7N7NS 4-Circuit Power Outlet Panel, 125 VAC, 20 A, Surface Mount
A power outlet panel (or POP) is a device designed for outdoor service to meet temporary power requirements at construction sites and RV parks. POPs provide a safe and reliable means for users to access electricity at such locations.
EATON Crouse-Hinds CD1 SA Straight Conduit Drain, 1/2 in MNPT, For Use With Conduit System, Copper-Free Aluminum, Chromate Treated Electro-Galvanized
Crouse-Hinds series CD drains are for use in ordinary location conduit systems to drain accumulated condensate and provide ventilation to minimize condensation. Drains are installed in hubs or drilled and tapped openings.
EATON Crouse-Hinds CD2 SA Straight Conduit Drain, 3/4 in MNPT, For Use With Conduit System, Copper-Free Aluminum
Crouse-Hinds series CD drains are for use in ordinary location conduit systems to drain accumulated condensate and provide ventilation to minimize condensation. Drains are installed in hubs or drilled and tapped openings.
Recently Viewed
THE ARC ABRASIVES ROLL IS SPECIFICALLY ENGINEERED FOR APPLICATIONS SUCH AS: STOCK REMOVAL, DEBURRING, FLASH REMOVAL, SURFACE PREPARATION, AND FINISHING. PERFECT FOR USE ON ALUMINUM AND VARIOUS METALS.
-ARC73139 >
EACH BLADE MARKED WITH SIZE IN METRIC AND DECIMAL. VINYL CASE HAS INDIVIDUAL BLADE PACKETS, CONVENIENTLY FOLDS FLAT
-PRC19740 >
5/16" X 1-1/2" USS SKT SET SCREWS-HOL32158>
#60-2 RIVETED ROLLER CHAIN >(FT)-BRWJ602RIV10FTCH >
1/2" X 9" A-TAPER ROTARY HAMMER BITS-GALA5009 >
MEDIUM DUTY 2-1-1/16" ID INSERT BEARING-BRWVS343 >