Schneider Electric Square D™ TeSys™ D LC1D12BD Direct On-Line Standard IEC Contactor, 690 V AC, 24/300 V DC V Coil, 12/25 A, 3NO Contact, 3 Poles
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3/3e (5.5kW@400V). They can be used to create motor starters for almost any type of application. It provides a 24V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 3HP at 200-208VAC, 3HP at 240VAC, 7.5HP at 480VAC and 10HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 30A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.74 inches deep. It weighs 1.07 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
EATON XTCE040D00A Full Voltage Non-Reversing IEC Contactor, 110/120 V AC V Coil, 40 A, 0NO-0NC Contact, 3 Poles
Small size. Big impact. The XT IEC contactors are powerful, efficient and versatile, and can be combined with our full range of electronic overload relays and bimetal relays. These DC devices stand out for their reduced power consumption, which makes them more energy efficient and also reduces the size of the power supply units. XT IEC contactors are suitable for global use and cover the entire output range, from mini contactor relays (up to 7 A) all the way to vacuum contactors (up to 3180 A).
Recently Viewed
EATON CHFN115DF Type CH Dual Function Arc Fault/Ground Fault Combination Circuit Breaker, 120/240 V AC, 15 A, 10 kA Interrupt, 1 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
1100T HUB X 3-7/8 Dodge® Grid-Lign® 006471 Finished Bore Horizontal/Vertical Split Cover Grid Coupling Hub, 1100T Coupling, Steel
1100T HUB X 3-7/8 Dodge® Grid-Lign® 006471 Finished Bore Horizontal/Vertical Split Cover Grid Coupling Hub, 1100T Coupling, Steel
32" X 32" X 1" AIR FILTER - GLATA32321 >
Square D™ EDB14020 Type EDB Molded Case Standard E-FRAME Miniature Circuit Breaker, 277 V AC, 20 A, 18 kA Interrupt, 1 Pole, Thermal Magnetic Trip
E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 20A, 1 pole, and has an operating voltage of 277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. This product is UL Listed as Switching duty and High Intensity Discharge. HACR rated.
Square D™ EDB34020 Type EDB Molded Case Standard E-FRAME Miniature Circuit Breaker, 277/480Y V AC, 20 A, 18 kA Interrupt, 3 Poles, Thermal Magnetic Trip
E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 20A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 270A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 875A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
GENERAL® 557 Flat Inspection Mirror, 2-1/4 in Mirror, Round Shape, 10-1/2 to 15 in L, Telescoping Cushion Grip Handle
GENERAL® 557 Flat Inspection Mirror, 2-1/4 in Mirror, Round Shape, 10-1/2 to 15 in L, Cushion Grip/Telescopic Handle