Littelfuse® POWR-GARD® SLC060 Current Limiting Medium Acting Time Delay Fuse, 60 A, 480 V AC, 100 kA Interrupt, G Class, Cartridge Body
The unique design of Littelfuse® compact SLC series Class G fuses provide additional time delay over competitive products which increases system reliability. Compact Class G fuses were the first fuse series to approach midget fuse dimensions and meet NEC requirements for branch-circuit protection. The unique dimensions of SLC series Class G fuses prevents insertion of lower voltage fuses in Class G fuse holders. The fuse's varying length prevents insertion of higher ampere rated fuses in fuse holders designed for lower ampere ratings. Class CC fuses are replacing Class G fuses in many new designs. Class CC fuses' superior time delay plus higher voltage and interrupting ratings meet the needs of modern circuits. Littelfuse® introduction of POWR-PRO® CCMR series fuses, with ratings upto 60 A for providing branch circuit protection are accelerating this trend.
-
BrandLittelfuse®
-
UPC079458420784
-
Manufacturer Part NumberSLC060
-
CountryUSA
-
Terminal TypeFerrule
-
ClassG
-
TypeCurrent Limiting Medium Acting
-
Mounting TypeHolder
-
Voltage Rating480 V AC
-
Amperage Rating60 A
-
SeriesSLC
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating100 kA
-
Body Size13/32 in Dia x 2-1/4 in L
-
Body TypeCartridge
- Current limiting design reduces damage to equipment caused by heating and magnetic effects of short circuit currents
- Medium time-delay allows fuses to be sized closer to actual equipment requirements no need to greatly oversize to withstand harmless equipment or system surges
- Medium time-delay may reduce downtime caused by power surges or equipment demands
- 100 kA at 480 VAC interrupting rating
| Competitor Name | Competitor Part Number |
|---|---|
| Grainger | 486K38 |
-
Alternative Part Number0SLC060.T|8588246
-
UNSPSC39121627
-
IDEA Index ID8588246
-
Package DescriptionEACH
-
Standards/ApprovalsUL 248-5|E81895|CSA Certified|PROP65: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer
-
Specification Sheet
-
Owners/User Manual
-
Full Engineering Drawing
-
Technical Bulletin
Recently Viewed
Littelfuse® POWR-GARD® SLC060 Current Limiting Medium Acting Time Delay Fuse, 60 A, 480 V AC, 100 kA Interrupt, G Class, Cartridge Body
The unique design of Littelfuse® compact SLC series Class G fuses provide additional time delay over competitive products which increases system reliability. Compact Class G fuses were the first fuse series to approach midget fuse dimensions and meet NEC requirements for branch-circuit protection. The unique dimensions of SLC series Class G fuses prevents insertion of lower voltage fuses in Class G fuse holders. The fuse's varying length prevents insertion of higher ampere rated fuses in fuse holders designed for lower ampere ratings. Class CC fuses are replacing Class G fuses in many new designs. Class CC fuses' superior time delay plus higher voltage and interrupting ratings meet the needs of modern circuits. Littelfuse® introduction of POWR-PRO® CCMR series fuses, with ratings upto 60 A for providing branch circuit protection are accelerating this trend.
CONTAINS 100% MINERAL SPIRITS, THINS OIL BASED PAINTS, STAINS, AND VARNISHES. CLEANS BRUSHES AND QEUIPMENT AFTER PAINTING.
-JWH775888 >
775398 DO-IT-BEST/SAVOGRAN STRYPEEZE QUART METHYLENE CHLORIDE FREE STRIPPER
GENERAL PURPOSE METHYLENE CHLORIDE FREE STRIPPER REMOVES PAINT, VARNISH AND MOST FINISHES WITHOUT HARMING WOOD, METAL OR MASONRY. SEMI-PASTE FOR BRUSH APPLICATION. EXCLUSIVE FORMULA IMPROVES CLING AND CUTTING POWER ON ROUNDED SURFACES. STAYS WET LONGER AND CUTS DEEPER. WATER RINSABLE FOR EASY CLEANUP.
-JWH775398>
Littelfuse® POWR-GARD® SLC035 Current Limiting Medium Acting Time Delay Fuse, 35 A, 480 V AC, 100 kA Interrupt, G Class, Cartridge Body
The unique design of Littelfuse® compact SLC series Class G fuses provide additional time delay over competitive products which increases system reliability. Compact Class G fuses were the first fuse series to approach midget fuse dimensions and meet NEC requirements for branch-circuit protection. The unique dimensions of SLC series Class G fuses prevents insertion of lower voltage fuses in Class G fuse holders. The fuse's varying length prevents insertion of higher ampere rated fuses in fuse holders designed for lower ampere ratings. Class CC fuses are replacing Class G fuses in many new designs. Class CC fuses' superior time delay plus higher voltage and interrupting ratings meet the needs of modern circuits. Littelfuse® introduction of POWR-PRO® CCMR series fuses, with ratings upto 60 A for providing branch circuit protection are accelerating this trend.
Littelfuse® POWR-GARD® SLC025 Current Limiting Medium Acting Time Delay Fuse, 25 A, 480 V AC, 100 kA Interrupt, G Class, Cartridge Body
The unique design of Littelfuse® compact SLC series Class G fuses provide additional time delay over competitive products which increases system reliability. Compact Class G fuses were the first fuse series to approach midget fuse dimensions and meet NEC requirements for branch-circuit protection. The unique dimensions of SLC series Class G fuses prevents insertion of lower voltage fuses in Class G fuse holders. The fuse's varying length prevents insertion of higher ampere rated fuses in fuse holders designed for lower ampere ratings. Class CC fuses are replacing Class G fuses in many new designs. Class CC fuses' superior time delay plus higher voltage and interrupting ratings meet the needs of modern circuits. Littelfuse® introduction of POWR-PRO® CCMR series fuses, with ratings upto 60 A for providing branch circuit protection are accelerating this trend.
Littelfuse® POWR-GARD® SLC005 Current Limiting Medium Acting Time Delay Fuse, 5 A, 600 V AC, 100 kA Interrupt, G Class, Cartridge Body
The unique design of Littelfuse® compact SLC series Class G fuses provide additional time delay over competitive products which increases system reliability. Compact Class G fuses were the first fuse series to approach midget fuse dimensions and meet NEC requirements for branch-circuit protection. The unique dimensions of SLC series Class G fuses prevents insertion of lower voltage fuses in Class G fuse holders. The fuse's varying length prevents insertion of higher ampere rated fuses in fuse holders designed for lower ampere ratings. Class CC fuses are replacing Class G fuses in many new designs. Class CC fuses' superior time delay plus higher voltage and interrupting ratings meet the needs of modern circuits. Littelfuse® introduction of POWR-PRO® CCMR series fuses, with ratings upto 60 A for providing branch circuit protection are accelerating this trend.