Littelfuse® POWR-GARD® SLC005 Current Limiting Medium Acting Time Delay Fuse, 5 A, 600 V AC, 100 kA Interrupt, G Class, Cartridge Body
The unique design of Littelfuse® compact SLC series Class G fuses provide additional time delay over competitive products which increases system reliability. Compact Class G fuses were the first fuse series to approach midget fuse dimensions and meet NEC requirements for branch-circuit protection. The unique dimensions of SLC series Class G fuses prevents insertion of lower voltage fuses in Class G fuse holders. The fuse's varying length prevents insertion of higher ampere rated fuses in fuse holders designed for lower ampere ratings. Class CC fuses are replacing Class G fuses in many new designs. Class CC fuses' superior time delay plus higher voltage and interrupting ratings meet the needs of modern circuits. Littelfuse® introduction of POWR-PRO® CCMR series fuses, with ratings upto 60 A for providing branch circuit protection are accelerating this trend.
-
BrandLittelfuse®
-
UPC079458420555
-
Manufacturer Part NumberSLC005
-
CountryUSA
-
Terminal TypeFerrule
-
ClassG
-
TypeCurrent Limiting Medium Acting
-
Mounting TypeHolder
-
Voltage Rating600 V AC
-
Amperage Rating5 A
-
SeriesSLC
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating100 kA
-
Body Size13/32 in Dia x 1-5/16 in L
-
Body TypeCartridge
- Current limiting design reduces damage to equipment caused by heating and magnetic effects of short circuit currents
- Medium time-delay allows fuses to be sized closer to actual equipment requirements no need to greatly oversize to withstand harmless equipment or system surges
- Medium time-delay may reduce downtime caused by power surges or equipment demands
- 100 kA at 600 VAC interrupting rating
| Competitor Name | Competitor Part Number |
|---|---|
| Grainger | 486K26 |
-
Alternative Part Number0SLC005.T|8588151
-
UNSPSC39121627
-
IDEA Index ID8588151
-
Package Description10/BX
-
Standards/ApprovalsUL 248-5|E81895|CSA Certified|PROP65: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer
-
Specification Sheet
-
Owners/User Manual
-
Full Engineering Drawing
-
Technical Bulletin
Recently Viewed
Littelfuse® POWR-GARD® SLC005 Current Limiting Medium Acting Time Delay Fuse, 5 A, 600 V AC, 100 kA Interrupt, G Class, Cartridge Body
The unique design of Littelfuse® compact SLC series Class G fuses provide additional time delay over competitive products which increases system reliability. Compact Class G fuses were the first fuse series to approach midget fuse dimensions and meet NEC requirements for branch-circuit protection. The unique dimensions of SLC series Class G fuses prevents insertion of lower voltage fuses in Class G fuse holders. The fuse's varying length prevents insertion of higher ampere rated fuses in fuse holders designed for lower ampere ratings. Class CC fuses are replacing Class G fuses in many new designs. Class CC fuses' superior time delay plus higher voltage and interrupting ratings meet the needs of modern circuits. Littelfuse® introduction of POWR-PRO® CCMR series fuses, with ratings upto 60 A for providing branch circuit protection are accelerating this trend.
3/4" X 60-YDS #519 MASKING TAPE-ATC73848 >
1/4" LYNCH PIN CHAIN/COTTER-MED6309 >
Edison KON100 One-Time Fuse, 100 A, 250 VAC, 10 kA Interrupt, Class: Class H
Lift-All® Tuflex™ EN90X12 Endless Round Sling, 12 ft L, 8400 lb, Polyester, Yellow
Tuflex endless roundslings are the most versitile roundsling. Tuflex roundslings are color-coded to easily identified capacities . The cover is seamless with no sewn edges, preventing rupture and allowing wear points to be shifted to extend sling life.
CRC® 03180 Quick-Clean™ Chlorinated Non-Flammable Degreaser, 20 oz Aerosol Can, Strong in High Concentrations Odor/Scent, Clear, Liquid Form
Effective degreasing action with fast evaporation and no residue. The non-flammable, VOC exempt formula contains no Class I or Class II Ozone Depleting Chemicals. Use caution on plastics and paints.