QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 2 pole QO circuit breaker is rated at 15A at 120/240VAC. This unit provides 10kA breaking capacity and plug in mounting. This product includes a 6mA ground fault A with pigtail. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.
Leviton® 5054 Non-Grounding Straight Blade Receptacle, 125/250 VAC, 30 A, 3 Poles, 3 Wires, Black
Built of durable thermoplastic, Leviton® power receptacles - come equipped with heavy gauge, double wire copper alloy contacts. To ensure correct and speedy wiring, terminals have ID markings.
Square-D 40-AMP 3-POLE 240-VOLT CONTACTORS SQU 8910-DPA-43-V-09
8910DP definite purpose magnetic contactors are designed for heating, air conditioning and refrigeration applications. This line of definite purpose contactors has current ratings up to 120 amperes resistive and 50 HP at 600 VAC. This three pole definite purpose contactor has a full load rating of 40 ampere and a resistive rating of 50 amperes. It also has a 3 HP at 115 VAC single phase, 7.5 HP at 230 VAC single phase and 10 HP at 230 VAC three phase, 20 HP at 460 VAC three phase and 25 HP at 575 VAC three phase. The nonreplaceable coil is available with a variety of coil voltages. This device has a 208/240 VAC 60 Hz, 220 VAC 50 Hz coil. The contactor has straight through wiring. Contactor is 3.75 inches by 2.37 inches and 3.00 tall. These contactors are UL component recognized and CSA certified.
EATON BR325 Type BR Circuit Breaker, 240 V AC, 25 A, 10 kA Interrupt, 3 Poles
Eaton’s BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF.
G-213-1/2 CROSBY MATERIAL HANDLING GROUP 1/2" 2-TON SHACKLES
Working Load Limit: 2 tons
Safety Factor: 6:1
Inside Width: 1.31"
Inside Height: 1.88"
Mouth Width: 0.81"
Shackle Size: 1/2"
Pin Size: 5/8"
Material: Carbon Steel Shackle
Alloy Pin
Finish: Galvanized
Type: Round Pin Anchor
Product Weight: .7 lbs.
Standards: Meets or exceeds all requirements of Federal Specification RR-C-271 & ASTM A148M.