POWERS 3/8" X 2-1/4" S/S CONCRETE ANCHORS PWR 7310
The Power-Stud® anchor, is a fully threaded, torque-controlled, wedge expansion anchor. It is available in a threaded version suitable for applications in solid concrete and grout-filled concrete masonry. The threaded version is produced in type 304 and type 316 stainless steel.
-
BrandDeWALT®
-
UPC753520731014
-
Manufacturer Part Number07310-PWR
-
CountryUSA
-
Tensile Strength4075 lb
-
Thread Length1-1/4 in
-
Material304 Stainless Steel
-
Thread Size3/8-16
-
Thread TypeUNC
-
Maximum Work Thickness5/8 in
-
Minimum Embedment Depth1-5/8 in
-
Shear Strength3760 lb
-
Diameter3/8 in
-
Drill Size3/8 in
-
Overall Length2-1/4 in
- Fully threaded, medium duty all-purpose anchor
- Anchors can be installed through the fixture for hole spotting not required
- Clip design prevents spinning during installation
- Length ID stamped on each threaded anchor
- Chamfered impact section prevents damage to threads
- Nominal drill bit diameter same as anchor diameter
| Competitor Name | Cross-Reference Number |
|---|---|
| Fastenal | 2140559 |
-
UNSPSC31162102
-
Standards/ApprovalsASTM E488|FM Approved|Federal GSA Specifications|GSA: A-A-1923A|UL File No. EX1289
Recently Viewed
The Power-Stud® anchor, is a fully threaded, torque-controlled, wedge expansion anchor. It is available in a threaded version suitable for applications in solid concrete and grout-filled concrete masonry. The threaded version is produced in type 304 and type 316 stainless steel.
The drum adapter in conjunction with motor head 8945 can be used on a standard 55 Gallon barrel to create a huge vacuum cleaner for the biggest jobsites. Place motor head on top of drum adapter and the gasket creates suction to hold the motor securely while the vacuum is in operation. Uses 16 in. accessories.
Dodge® 070377 Type S2000 Pillow Block Roller Bearing Unit, 4-15/16 in Dia Bore, 15 to 16 in L Bolt Center-to-Center, 5-1/2 in Base to Bore Centerline, 18.63 in OAL x 11.13 in OAH
Dodge® 070377 Type S2000 Pillow Block Roller Bearing Unit, 4-15/16 in Dia Bore, 15 to 16 in L Bolt Center-to-Center, 5-1/2 in Base to Bore Centerline, 18.63 in OAL x 11.13 in OAH
HCI Preferred Supplier 944428 Lift In-Line Check Valve, 1/4 in Nominal, NPT End Style, Forged Brass Body
HCI Preferred Supplier 944428 Lift In-Line Check Valve, 1/4 in Nominal, NPT End Style, Forged Brass Body
EATON BRP30B200 1-Phase Main Breaker Load Center, 120/240 V AC, 200 A, 1 Poles, 25 kA Interrupt
Specially designed for easy installation, Eaton's BR 1-inch load centers house the branch circuit breakers and the wiring required to distribute power to individual circuits. They serve as main breaker for service entrances or as main lug when adding circuits to existing service. The main breaker protects the entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.
Gardner Bender PushGard™ 19-PC2 2-Port Push-In Wire Connector With Corrosion Resistant Stainless Steel Spring, 22 to 12 AWG Solid Copper Wire, Polycarbonate
Fast and easy to use, just strip and push conductors into Gardner Bender PushGard connectors to make reliable, secure connections. This case of ten red push-in connectors restrict wire pullout, yet connections are possible with a simple left-right twist and pull. Made of corrosion-resistant stainless steel springs, these connectors have a clear-carbonate housing with color-coded side panels for ease in connection verification and identification.