EATON CH225 Type CH Standard Molded Case Circuit Breaker, 120/240 VAC, 25 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
EATON has enhanced its premium Type CH residential circuit breakers, making the best even better. These features further establish the CH series of products as Best in Class. EATON offers CH 3/4 in circuit breakers with a thermal-magnetic trip curve that avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions.
-
BrandCutler-Hammer
-
UPC782113121451
-
Manufacturer Part NumberCH225
-
CountryUSA
-
Temperature Rating40 deg C
-
MaterialBakelite
-
Trip TypeThermal Magnetic
-
ColorBlack
-
TypeType CH Standard
-
Mounting TypePlug-On
-
Actuator Type2-Position Handle
-
Voltage Rating120/240 V AC
-
Amperage Rating25 A
-
Wire Size(1) 14 to 8 AWG, (2) 14 to 10 AWG
-
Number of Poles2
-
Dimensions3-1/2 in L x 1-1/2 in W x 3-1/2 in H
-
Interrupt Rating10 kA
-
Enclosure TypeNEMA 1/3R
-
Phase1
- Space-saving 3/4 in design accommodates more breakers per panel
- Tri-drive screw accepts flat, Robertson or Phillips drivers, making it easier for electricians to install
- Single and 2-pole breakers up to 50 A
- Units feature a quick-make, Quick-break switch mechanism combined with inverse time element tripping operation and trip-free handle design
- Type CH circuit breakers trip to the Off position, eliminating nuisance call backs
- Type CH interiors feature 100% copper bus
- Copper/aluminum wire
- 2-pole requires two 3/4 in space
-
Alternative Part Number7337153
-
UNSPSC39121601
-
IDEA Index ID7337153
-
Package DescriptionEACH
-
Standards/ApprovalsCCC Certified|CE Certified|CSA Certified|Lloyd's Register Certified|Bureau Veritas Certified|GOST-R Certified|UL 489
-
WarrantyLimited Lifetime
-
Catalog
Recently Viewed
EATON CH225 Type CH Standard Molded Case Circuit Breaker, 120/240 VAC, 25 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
EATON has enhanced its premium Type CH residential circuit breakers, making the best even better. These features further establish the CH series of products as Best in Class. EATON offers CH 3/4 in circuit breakers with a thermal-magnetic trip curve that avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions.
EATON BR260 Type BR Circuit Breaker, 120/240 V AC, 60 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton’s BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF.
EATON BR230 Type BR Circuit Breaker, 120/240 V AC, 30 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton’s BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF.
EATON BR220 Type BR Circuit Breaker, 120/240 V AC, 20 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton’s BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF.
EATON CHB115 Type CHB Standard Molded Case Circuit Breaker, 120/240 V AC, 15 A, 10 kA Interrupt, 1 Poles, Thermal Magnetic Trip
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
Milwaukee® 3651-20 Compact Brushless Hex Impact Driver, 1/4 in Drive Hex Drive, 0 to 4900 bpm, 1700 in-lb Torque Rating, 18 V, 4.4 in OAL
The MILWAUKEE® M18™ Compact Brushless ¼” Hex 3-Speed Impact Driver is more compact and more capable. Measuring only 4.4" in length and 2.1" in width, the compact size allows for better access in tight spaces while being lightweight and portable. The 3-Mode Drive Control™ provides greater control over output speed and power. The brushless motor technology provides 1,700 in-lbs. of torque and up to 3600 RPMs for faster speed and increased productivity. MILWAUKEE® REDLINK™ Intelligence optimizes the way the M18™ REDLITHIUM™ batteries work with the impact driver for best-in-class performance. Premium components and an all metal gearcase provide durability that professionals require. The Compact Brushless ¼” Hex 3-Speed Impact Driver is part of the M18™ system, fully compatible with over 250+ solutions.