Littelfuse® POWR-GARD® NLN060 Fast Blow One Time Fuse, 60 A, 250 V AC/DC, 20/50 kA Interrupt, Class: K5, Cartridge Body
NLN series fuses provide low cost protection for general purpose feeder and branch circuits when available short circuit currents are less than 50000 A. They replace all Class H fuses which have only a 10000 A interrupting rating. They are suitable for use in many residential and smaller commercial and industrial applications. NLKP series fuses are Canadian "Code" fuses specifically designed to meet Canadian electrical code type P fuse requirements for residential use. They have a 10000 A interrupting rating. However, to obtain the added benefits of time delay, current limitation and higher interrupting rating, consider the use of POWR-PRO® IDSR Indicator fuses for circuits between 250 and 600 V. The user gets all the benefits of time delay RK5 fuses plus the added benefits of a n indicating fuse that tells when it has opened. complete information on these fuses may be found in the POWR-PRO® section of this catalog. for circuits upto 250 V, see FLNR fuses in this section of the catalog.
-
BrandLittelfuse®
-
UPC079458360783
-
Manufacturer Part NumberNLN060
-
CountryUSA|Canada
-
Terminal TypeFerrule
-
ClassK5
-
Frequency Rating50/60 Hz
-
TypeFast Blow
-
Mounting TypeHolder
-
Voltage Rating250 V AC/DC
-
Amperage Rating60 A
-
SeriesNLN
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating20/50 kA
-
Body Size13/16 in Dia x 3 in L
-
Body TypeCartridge
-
ElementSingle
- For use in applications where lowest initial cost is the major consideration
- Economical
- 50 kA at 250 VAC (rms symmetrical) and 20 kA at 250 VDC interrupt rating
- Safety - 50000 A.I.R., Class K5 adequate interrupting capacity for residences and many smaller facilities
-
Alternative Part Number0NLN060.T|8586774
-
UNSPSC39121627
-
IDEA Index ID8586774
-
Package DescriptionEACH
-
Standards/ApprovalsUL E81895|CSA LR29862, Standard 248-9|PROP65: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer
-
Specification Sheet
-
Owners/User Manual
-
Full Engineering Drawing
-
Technical Bulletin
Recently Viewed
Littelfuse® POWR-GARD® NLN060 Fast Blow One Time Fuse, 60 A, 250 V AC/DC, 20/50 kA Interrupt, Class: K5, Cartridge Body
NLN series fuses provide low cost protection for general purpose feeder and branch circuits when available short circuit currents are less than 50000 A. They replace all Class H fuses which have only a 10000 A interrupting rating. They are suitable for use in many residential and smaller commercial and industrial applications. NLKP series fuses are Canadian "Code" fuses specifically designed to meet Canadian electrical code type P fuse requirements for residential use. They have a 10000 A interrupting rating. However, to obtain the added benefits of time delay, current limitation and higher interrupting rating, consider the use of POWR-PRO® IDSR Indicator fuses for circuits between 250 and 600 V. The user gets all the benefits of time delay RK5 fuses plus the added benefits of a n indicating fuse that tells when it has opened. complete information on these fuses may be found in the POWR-PRO® section of this catalog. for circuits upto 250 V, see FLNR fuses in this section of the catalog.
Posi Lock® 10858 Center Bolt, For Use With 8 in 108 and 208 Puller, 3/4 in Dia
Posi Lock® 10858 Center Bolt, For Use With 8 in 108 and 208 Puller, 3/4 in Dia
BBI 859260 2-Way Reversible Lock Nut, 3/8-16, Low Carbon Steel, Zinc CR+3, A Material Grade, Right Thread
BBI 859260 2-Way Reversible Lock Nut, 3/8-16, Low Carbon Steel, Zinc CR+3, A Material Grade, Right Thread
External Snap Ring Assortment, 1/8 to 1-1/16 in, 300 Pieces, Steel
32-OZ FOAM CUP SMALL BOTTOM-CS/400-WHY32AJ20H >
1-1/8" X 36" COLD ROLLED SHAFTING - JMSCR11/8 >