Littelfuse® POWR-GARD® NLN500 Fast Blow One Time Fuse, 500 A, 250 V AC/DC, 50 kA Interrupt, Class: K5, Cartridge Body
NLN series fuses provide low cost protection for general purpose feeder and branch circuits when available short circuit currents are less than 50000 A. They replace all Class H fuses which have only a 10000 A interrupting rating. They are suitable for use in many residential and smaller commercial and industrial applications. NLKP series fuses are Canadian "Code" fuses specifically designed to meet Canadian electrical code type P fuse requirements for residential use. They have a 10000 A interrupting rating. However, to obtain the added benefits of time delay, current limitation and higher interrupting rating, consider the use of POWR-PRO® IDSR Indicator fuses for circuits between 250 and 600 V. The user gets all the benefits of time delay RK5 fuses plus the added benefits of a n indicating fuse that tells when it has opened. complete information on these fuses may be found in the POWR-PRO® section of this catalog. for circuits upto 250 V, see FLNR fuses in this section of the catalog.
-
BrandLittelfuse®
-
UPC079458360967
-
Manufacturer Part NumberNLN500
-
CountryUSA|Canada
-
Terminal TypeKnife Blade
-
ClassK5
-
Frequency Rating50/60 Hz
-
TypeFast Blow
-
Mounting TypeHolder
-
Voltage Rating250 V AC/DC
-
Amperage Rating500 A
-
SeriesNLN
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating50 kA
-
Body Size2-19/32 in Dia x 10-3/8 in L
-
Body TypeCartridge
-
ElementSingle
- For use in applications where lowest initial cost is the major consideration
- Economical
- 50 kA at 250 VAC (rms symmetrical) and 50 kA at 250 VDC interrupt rating
- Safety - 50000 A.I.R., Class K5 adequate interrupting capacity for residences and many smaller facilities
-
Alternative Part Number0NLN500.X|8586907
-
UNSPSC39121627
-
IDEA Index ID8586907
-
Package DescriptionEACH
-
Standards/ApprovalsUL E81895|CSA LR29862, Standard 248-9
-
Specification Sheet
-
Owners/User Manual
-
Full Engineering Drawing
-
Technical Bulletin
Recently Viewed
Littelfuse® POWR-GARD® NLN500 Fast Blow One Time Fuse, 500 A, 250 V AC/DC, 50 kA Interrupt, Class: K5, Cartridge Body
NLN series fuses provide low cost protection for general purpose feeder and branch circuits when available short circuit currents are less than 50000 A. They replace all Class H fuses which have only a 10000 A interrupting rating. They are suitable for use in many residential and smaller commercial and industrial applications. NLKP series fuses are Canadian "Code" fuses specifically designed to meet Canadian electrical code type P fuse requirements for residential use. They have a 10000 A interrupting rating. However, to obtain the added benefits of time delay, current limitation and higher interrupting rating, consider the use of POWR-PRO® IDSR Indicator fuses for circuits between 250 and 600 V. The user gets all the benefits of time delay RK5 fuses plus the added benefits of a n indicating fuse that tells when it has opened. complete information on these fuses may be found in the POWR-PRO® section of this catalog. for circuits upto 250 V, see FLNR fuses in this section of the catalog.
IKO manufacturers a variety of durable Roller Followers that feature needle rollers embedded in a thick outer ring, specifically designed for smooth outer ring rotation. Crowned and cylindrical outer ring styles meet a diverse range of application needs. Outer rings run directly on mating track surfaces.
48" X 96" X 1/16" ABS PLASTIC
Dixon® 4PS8 Dual Lock Thor Interchange Quick Acting Coupling With Locking Sleeve, 1 in, Hose Barb, Steel, Plated
Dixon® 4PS8 Dual Lock Thor Interchange Quick Acting Coupling With Locking Sleeve, 1 in, Hose Barb, Steel, Plated
Littelfuse® POWR-GARD® NLN080 Fast Blow One Time Fuse, 80 A, 250 V AC/DC, 50 kA Interrupt, Class: K5, Cartridge Body
NLN series fuses provide low cost protection for general purpose feeder and branch circuits when available short circuit currents are less than 50000 A. They replace all Class H fuses which have only a 10000 A interrupting rating. They are suitable for use in many residential and smaller commercial and industrial applications. NLKP series fuses are Canadian "Code" fuses specifically designed to meet Canadian electrical code type P fuse requirements for residential use. They have a 10000 A interrupting rating. However, to obtain the added benefits of time delay, current limitation and higher interrupting rating, consider the use of POWR-PRO® IDSR Indicator fuses for circuits between 250 and 600 V. The user gets all the benefits of time delay RK5 fuses plus the added benefits of a n indicating fuse that tells when it has opened. complete information on these fuses may be found in the POWR-PRO® section of this catalog. for circuits upto 250 V, see FLNR fuses in this section of the catalog.
.276EX TERNAL RETAINING RING

