Littelfuse® POWR-GARD® NLN175 Fast Blow One Time Fuse, 175 A, 250 V AC/DC, 50 kA Interrupt, Class: K5, Cartridge Body
NLN series fuses provide low cost protection for general purpose feeder and branch circuits when available short circuit currents are less than 50000 A. They replace all Class H fuses which have only a 10000 A interrupting rating. They are suitable for use in many residential and smaller commercial and industrial applications. NLKP series fuses are Canadian "Code" fuses specifically designed to meet Canadian electrical code type P fuse requirements for residential use. They have a 10000 A interrupting rating. However, to obtain the added benefits of time delay, current limitation and higher interrupting rating, consider the use of POWR-PRO® IDSR Indicator fuses for circuits between 250 and 600 V. The user gets all the benefits of time delay RK5 fuses plus the added benefits of a n indicating fuse that tells when it has opened. complete information on these fuses may be found in the POWR-PRO® section of this catalog. for circuits upto 250 V, see FLNR fuses in this section of the catalog.
-
BrandLittelfuse®
-
UPC079458360875
-
Manufacturer Part NumberNLN175
-
CountryUSA
-
Terminal TypeKnife Blade
-
ClassK5
-
Frequency Rating50/60 Hz
-
TypeFast Blow
-
Mounting TypeHolder
-
Voltage Rating250 V AC/DC
-
Amperage Rating175 A
-
SeriesNLN
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating50 kA
-
Body Size1-9/16 in Dia x 7-1/8 in L
-
Body TypeCartridge
-
ElementSingle
- For use in applications where lowest initial cost is the major consideration
- Economical
- 50 kA at 250 VAC (rms symmetrical) and 50 kA at 250 VDC interrupt rating
- Safety - 50000 A.I.R., Class K5 adequate interrupting capacity for residences and many smaller facilities
-
Alternative Part Number0NLN175.X|8586846
-
UNSPSC39121627
-
IDEA Index ID8586846
-
Package DescriptionEACH
-
Standards/ApprovalsUL E81895|CSA LR29862, Standard 248-9
-
Specification Sheet
-
Owners/User Manual
-
Full Engineering Drawing
-
Technical Bulletin
Recently Viewed
Littelfuse® POWR-GARD® NLN175 Fast Blow One Time Fuse, 175 A, 250 V AC/DC, 50 kA Interrupt, Class: K5, Cartridge Body
NLN series fuses provide low cost protection for general purpose feeder and branch circuits when available short circuit currents are less than 50000 A. They replace all Class H fuses which have only a 10000 A interrupting rating. They are suitable for use in many residential and smaller commercial and industrial applications. NLKP series fuses are Canadian "Code" fuses specifically designed to meet Canadian electrical code type P fuse requirements for residential use. They have a 10000 A interrupting rating. However, to obtain the added benefits of time delay, current limitation and higher interrupting rating, consider the use of POWR-PRO® IDSR Indicator fuses for circuits between 250 and 600 V. The user gets all the benefits of time delay RK5 fuses plus the added benefits of a n indicating fuse that tells when it has opened. complete information on these fuses may be found in the POWR-PRO® section of this catalog. for circuits upto 250 V, see FLNR fuses in this section of the catalog.
8-MM X 10-MM SHOULDER BOLT-MET93608010 >
3" X 1/8" X 3/8" CUTOFF WHEEL, TYPE 1 ALUMINUM OXIDE METAL CUTTING WHEEL. DESIGNED FOR METAL CUTTING, METAL ABRASION, BODY WORK, METAL FABRICATION AND GENERAL REPAIR WORK
MORSE® 15475 1439 Drill Blank, #58 Drill Blank, 1-5/8 in L, HSS
CONSTRUCTED AS CURVED BEAMS OF UNIFORM STRENGTH, THE RADIAL WIDTH IS REDUCED TOWARDS THE FREE ENDS SO THAT A CONSTANTLY ROUND SHAP IS MAINTAINED THROUGHOUT CONTINUOUS USE. THIS FORM OF CIRCLIP OFTEN USED IN ASSEMBLIES SUBJECTED TO STRONG CENTRIFUGAL FORCES, IS ALSO SECURE AGAINST HIGH ROTATIONAL SPEEDS. LUGS WITH HOLES ARE PROVIDED FOR RAPID FITTING OR REMOVAL WITH CIRCLIP PLIERS.
- ANR1400475>
Leviton® OSFOA-W Offset Adapter, For Use With OSFHU Passive Infrared Fixture Mount High Bay Occupancy Sensor, 3-Position, Plastic, White
To improve the field of view for deep body fixtures, a separate offset adapter accessory (OSFOA-00W) can be used to position the sensor below the fixture body. The adapter simply snaps into a 1/2 in knockout ON the end of the industrial fixture to attach the sensor.