Edison ECNR3.2 ECNR Current Limiting Time Delay Fuse, 3.2 A, 250 V AC/125 V DC, 200 kAIC Interrupt, Class: RK5
Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
-
BrandEdison
-
UPC782634507185
-
Manufacturer Part NumberECNR3.2
-
CountryUSA
-
Terminal TypeFerrule
-
MaterialFiberglass
-
ClassRK5
-
Response Time8 s at 500%
-
TypeCurrent Limiting Time Delay
-
Mounting TypeClip
-
Voltage Rating250 V AC/125 V DC
-
Amperage Rating3.2 A
-
SeriesECNR
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating200 kAIC
-
Body Size0.56 in Dia x 2 in L
-
ElementDual
- True dual element construction allows sizing of 125% FLA for motor backup protection
- Superior overload and cycling capabilities
- Current limiting provides component short-circuit protection
- Recommended for AC power distribution system mains, feeders and branch circuits
- Protection of motors and motor branch circuits
- Protection of transformers and other inductive loads
-
Alternative Part Number11197122|16875614
-
UNSPSC39121606
-
IDEA Index ID11197122
-
Package DescriptionEACH
-
Standards/ApprovalsCE Certified|CSA C22.2 File No.700489/E162363/248.12 Guide JDDZ|UL Listed
-
Warranty12 months
-
Specification Sheet
Recently Viewed
Edison ECNR3.2 ECNR Current Limiting Time Delay Fuse, 3.2 A, 250 V AC/125 V DC, 200 kAIC Interrupt, Class: RK5
Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
Gates® Power Transmission Polyflex® 7M750 Light Duty V-Belt, 7M Section, 9/32 in W Top, 29.53 in L Outside, 7/32 in THK, High Modulus Polyurethane
Developed by Gates and produced to patented manufacturing processes, these belts provide more load-carrying capacity at higher speeds to small multiple V-belt precision drives. This results in significant cost savings and improved design freedom.
1/2" GLUING CLAMPS-TABGC12 >
5-GRIT 2001-A ASTRO-CUT WATER SOLUBLE-MNR34050 >
Charlotte PVC 02301 1600, 2 in nominal, Socket x FNPT end style, SCH 40/STD, PVC, Domestic
PVC Schedule 40 fitting that is for pressure systems where temperatures will not exceed 140° F. They are highly resilient, with high-tensile and high-impact strength. PVC Schedule 40 has better sound deadening qualities than
Browning 18-TOOTH #50-1 CHAIN SPROCKETS BRW H-5018 X 1.3/16
Browning® finished bore sprockets are offered in single strands. Offerings include 35 to 100 pitch range. Finished bore sprockets are available from 3/8 to 2-7/16 in. Hardened teeth are available up to 30 teeth.