Edison ECNR25 ECNR Current Limiting Time Delay Fuse, 25 A, 250 V AC/125 V DC, 200 kAIC Interrupt, Class: RK5, Cylindrical Body
Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
-
BrandEdison
-
UPC782634507338
-
Manufacturer Part NumberECNR25
-
CountryUSA
-
Terminal TypeFerrule End
-
MaterialFiberglass
-
ClassRK5
-
Rejection/Non-RejectionRejection
-
Response Time10 s at 500%
-
TypeCurrent Limiting Time Delay
-
Voltage Rating250 V AC/125 V DC
-
Amperage Rating25 A
-
SeriesECNR
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating200 kAIC
-
Body Size0.56 in Dia x 2 in L
-
Body TypeCylindrical
-
ElementDual
- Provides motor overload, ground fault and short circuit protection
- Helps protect motors against burnout from 1 ph on 3 ph systems
- Simplifies and improves blackout prevention (selective co-ordination ratios)
- Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is 5X greater than the amperage rating of the fuse for a minimum of 10 s
- Superior overload and cycling capabilities
- True dual element construction allows sizing of 125% FLA for motor backup protection
- Current limiting provides component short circuit protection
- For all general purpose applications including lighting, heating and other non-inductive loads
- Tin plated copper brass terminal and zinc plated steel screws
| Competitor Name | Competitor Part Number |
|---|---|
| Grainger | 12W253 |
-
Alternative Part Number11197133|10720500
-
UNSPSC39121606
-
IDEA Index ID11197133
-
Package DescriptionEACH
-
Standards/ApprovalsCE Certified|CSA C22.2 File No.700489/248.12|UL 248-12 File No.E162363 Guide JDDZ
-
Catalog
-
Specification Sheet
Recently Viewed
Edison ECNR25 ECNR Current Limiting Time Delay Fuse, 25 A, 250 V AC/125 V DC, 200 kAIC Interrupt, Class: RK5, Cylindrical Body
Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
3/8" -FEMALE PIPE THREADX6-FEMALE JIC HYDRAULIC ADAPTER-DAY650666 >
HYDRAULIC HOSE ENDS HY-0604-MP 108245-DAY4NP6SB >
Drillco 800A2018 Single End Tap and Drill Set, 18 Pieces
BBI 087138 Fully Threaded Cap Screw, 3/8-16, 1 in L Under Head, 5 Grade, Carbon Steel, Zinc CR+3
BBI 087138 Fully Threaded Cap Screw, 3/8-16, 1 in L Under Head, 5 Grade, Carbon Steel, Zinc CR+3
1/2"-ID S-FLEX COUPLING HALFS-LOV4J1/2>