Edison JDL15 Time Delay Fuse, 15 A, 600 V AC, 200 kA Interrupt, J Class
Edison's UL Class J fuse products are offered in both Dual-Element Time-Delay (JDL) and Fast-Acting (JFL) types. Both types have 200,000 amp interrupting rating at 600Vac RMS Sym amps. Their small physical size and high performance characteristics makes Class J fuses ideal for any space-limited applications. Edison's JFL fuses are best suited for the protection of non-inductive loads such as resistive heating and lighting circuits.
-
BrandEdison
-
UPC782634803379
-
Manufacturer Part NumberJDL15
-
CountryUSA
-
ClassJ
-
Voltage Rating600 V AC
-
Amperage Rating15 A
-
SeriesJDL
-
Interrupt Rating200 kA
-
Body Size0.81 in Dia x 2.25 in L
-
ElementDual
- True dual-element fuses with a minimum 10 s time delay at 500% overload
- Long time delay minimizes needless fuse openings due to temporary overloads and transient surges
- Can often be sized for back-up protection against motor burnout from overload or single-phasing if other overload protective devices fail
- High interrupting rating to safely interrupt overcurrent's up to 300 kA (self certified)
- High degree of current-limitation due to the fast speed-of-response to short-circuits
- Faster response to damaging short-circuit currents than mechanical overcurrent protective devices
- Reduces let-through thermal and magnetic forces in order to protect low withstand rated components
- Proper sizing provides no damage type 2 coordinated protection for NEMA and IEC motor control in accordance with IEC standard 947-4-1
- Dual-element fuses have lower resistance than ordinary fuses so they run cooler
- Lower watts loss reduces power consumption
- Unique dimensions assure that another class of fuse with a lesser voltage rating, interrupting rating or current-limiting ability cannot be substituted
- Space-saving package for equipment down sizing
- Use to protect lower interrupting rating circuit breakers, type 2 no damage protection of IEC style motor starters and contactors
-
Alternative Part Number8430311
-
UNSPSC39121626
-
IDEA Index ID8430311
-
Package DescriptionEACH
-
Standards/ApprovalsCE Certified|CSA Certified|HRCI-J 200, 000 AIR|Class J per CSA 22.2 No 248.8|Class 1422-02, File 53787|UL Class J, Guide JDDZ, File E162363
-
Specification Sheet
Recently Viewed
Edison's UL Class J fuse products are offered in both Dual-Element Time-Delay (JDL) and Fast-Acting (JFL) types. Both types have 200,000 amp interrupting rating at 600Vac RMS Sym amps. Their small physical size and high performance characteristics makes Class J fuses ideal for any space-limited applications. Edison's JFL fuses are best suited for the protection of non-inductive loads such as resistive heating and lighting circuits.
EATON BR2125 Type BR Circuit Breaker, 120/240 V AC, 125 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton’s BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF.
Browning® Classical Gripbelt® 1026160 AK Series Type 2 Single Groove Sheave, Finished Bore, 1/2 in Dia Bore, 3.05 in OD, 3 in (A)/2.46 in (3L) Dia Pitch, 21/32 in W Face
12" X 50' STANDARD ALUMINUM FLASHING - JWH101664 >
Apex® 323-1X Power Drive Bit, 4F-5R Slotted Point, 3 in OAL, Steel
IDEAL® Sir Nickless™ 35-782 Rotary Armored Cable Cutter, 5/16 to 3/8 in
The Sir Nickless protects armored cable wires by drawing the wires down, creating airspace above the wires and providing room for the cutter blade to shear through and sever the armored casing without nicking the wires within. The Sir Nickless is unique in that it has a curved design that allows the wires to draw down providing room for the cutting blade. The cable Cutter works well on all popular types of armored cable up to 3/8 inch diameter.