MORSE C/Tool 1/2" F/PITCH CBLT ROUGHING ENDMILL MCT 44981
MORSE® 44981 4613G Center Cutting Regular Length Roughing End Mill, 1/2 in Dia Cutter, 1-1/4 in Length of Cut, 4 Flutes, 1/2 in Dia Shank, 3-1/4 in OAL, TiN Coated
-
BrandMORSE®
-
UPC686125449810
-
Manufacturer Part Number44981
-
CountryUSA
-
FinishTiN Coated
-
MaterialM42 HSS-Co 8
-
Flute TypeFine Pitch
-
TypeCenter Cutting Regular Length
-
Helix Angle30 deg
-
Series4613G
-
Cutter Diameter1/2 in
-
Shank Diameter1/2 in
-
Number of Flutes4
-
Cutting DirectionRight Hand
-
Shank TypeRound/Weldon Flat
-
Length of Cut1-1/4 in
-
Overall Length3-1/4 in
- Roughing end mills feature a chip breaker type cutting edge for heavier cuts, higher speeds and feeds and greatly increased productivity
- Fine pitch is recommended for difficultto-machine, high tensile strength, abrasive and harder materials up to 40 rc
- Center cutting end allows for plunge cutting like a drill into solid material
- M42 8% cobalt offers increased wear and heat resistance for abrasive and difficult materials, higher speeds and feeds and long life in production applications
- Tool coatings further enhance milling performance
- External coolant
-
UNSPSC23242511
-
Package Description1/PK
-
Standards/ApprovalsISO 9001:2008
Recently Viewed
MORSE® 44981 4613G Center Cutting Regular Length Roughing End Mill, 1/2 in Dia Cutter, 1-1/4 in Length of Cut, 4 Flutes, 1/2 in Dia Shank, 3-1/4 in OAL, TiN Coated
Gates® Power Transmission PowerGrip® 170XL025 Extra Light Timing Belt, 1/4 in W, 17 in OAL, 0.2 in Pitch, 85 Teeth, Neoprene
The trapezoidal tooth profile of PowerGrip™ Timing belts offers a maintenance-free and economical alternative to conventional chain drives and is well suited for use in positioning applications.
1-1/2" -FEMALE PIPE THREAD BLACK STEEL COUPLING
1-1/8" -IDX1-3/8" -OD VITON O-RING
Weiler® 13119 Wheel Brush With Nut, 4 in Dia Brush, 1/2 in W Face, 0.02 in Dia Standard/Twist Knot Filament/Wire, 1/2-13 Arbor Hole
EATON CH215GFT Type CH Self-Test Ground Fault Circuit Breaker, 120/240 V AC, 15 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.