1060T TL (1615) HUB Dodge® Grid-Lign® 006321 Horizontal/Vertical Split Cover Taper-Lock® Bushed Grid Coupling Hub, 1060T Coupling, Steel
1060T TL (1615) HUB Dodge® Grid-Lign® 006321 Horizontal/Vertical Split Cover Taper-Lock® Bushed Grid Coupling Hub, 1060T Coupling, Steel
-
BrandDodge®
-
UPC782475258000
-
Manufacturer Part Number006321
-
CountryUSA
-
FinishAnti-Rust Coating
-
MaterialSteel
-
Maximum Speed3600 rpm
-
TypeHorizontal/Vertical Split Cover Taper-Lock® Bushed
-
Coupling Size1060T
-
Hub Diameter3 in
-
Length Through Bore2.1 in
-
Bore Diameter1/2 to 1-11/16 in
| Competitor Name | Competitor Part Number |
|---|---|
| Applied Industrial Technologies | 100943811 |
| Applied Industrial Technologies | 100943811 |
-
Alternative Part Number1060T TL (1615) HUB
-
UNSPSC31163009
-
Package Description1/PK
-
Standards/ApprovalsISO 9002|UL Listed
-
Specification Sheet
Recently Viewed
1060T TL (1615) HUB Dodge® Grid-Lign® 006321 Horizontal/Vertical Split Cover Taper-Lock® Bushed Grid Coupling Hub, 1060T Coupling, Steel
1060T TL (1615) HUB Dodge® Grid-Lign® 006321 Horizontal/Vertical Split Cover Taper-Lock® Bushed Grid Coupling Hub, 1060T Coupling, Steel
Each heater is identified by a catalog number stamped on one terminal. The heater application table indicates the range of full load motor current to which a given heater may be applied. Heaters should be selected on the basis of the actual full load current and service factor as shown on the motor nameplate or in the manufacturer's published literature. When motor and overload relay are in the same ambient and the service factor of the motor is 1.15 to 1.25, select heaters from the heater application table. If the service factor of the motor is 1 or there is no service factor shown or a maximum of 115% protection is desired, select one size smaller heater than indicated.
Eaton's Freedom starters and contactors feature a compact, space-saving design, using state-of-the-art technology and the latest in high strength, impact and temperature resistant insulating materials. In addition to the bimetallic overload, Eaton also offers a series of electronic overload relay (C440) available as a standalone unit and assembled with Freedom contactor.
Eaton's Freedom starters and contactors feature a compact, space-saving design, using state-of-the-art technology and the latest in high strength, impact and temperature resistant insulating materials. In addition to the bimetallic overload, Eaton also offers a series of electronic overload relay (C440) available as a standalone unit and assembled with Freedom contactor.
Each heater is identified by a catalog number stamped on one terminal. The heater application table indicates the range of full load motor current to which a given heater may be applied. Heaters should be selected on the basis of the actual full load current and service factor as shown on the motor nameplate or in the manufacturer's published literature. When motor and overload relay are in the same ambient and the service factor of the motor is 1.15 to 1.25, select heaters from the heater application table. If the service factor of the motor is 1 or there is no service factor shown or a maximum of 115% protection is desired, select one size smaller heater than indicated.
Eaton's Freedom starters and contactors feature a compact, space-saving design, using state-of-the-art technology and the latest in high strength, impact and temperature resistant insulating materials. In addition to the bimetallic overload, Eaton also offers a series of electronic overload relay (C440) available as a standalone unit and assembled with Freedom contactor.