Browning® 1125301 Double Strand Minimum Bore Type B Roller Chain Sprocket With Hardened Teeth, 3/4 to 1-1/2 in Dia Bore, 3.19 in OD, 35 Chain, 25 Teeth, 3/8 in Pitch, Steel
Browning®Type B minimum bore sprockets are offered in single, double and triple strands. Offerings include 25 to 200 pitch range. Minimum bore sprockets are available in bore ranges from 1/4 to 8-3/8 in.
-
BrandBrowning®
-
UPC662289319879
-
Manufacturer Part Number1125301
-
CountryUSA
-
Pitch Diameter2.992 in
-
MaterialSteel
-
Chain Size35
-
TypeDouble Strand Minimum Bore Type B
-
Hub Diameter2-1/4 in
-
Number of Teeth25
-
Outside Diameter3.19 in
-
Length Through Bore1-3/8 in
-
Bore Diameter3/4 to 1-1/2 in
- Larger hub diameter allows larger bore capacity
- Maximum bore shown will accommodate standard keyways and setscrews over keyway
- Slightly larger bores are possible with no keyway, shallow keyway or setscrew at angle to keyway
- Hub projection on one side
- High quality, high carbon steel
- Lasts longer than sprockets made from low carbon steel
- Large hub diameters, provides flexibility when reboring
- For use with 3/8 in pitch ANSI chain
-
Alternative Part NumberD35B25
-
UNSPSC31171901
-
Package Description1/PK
-
Warranty1 Year
-
Specification Sheet
-
Warranty Information
Recently Viewed
Browning® 1125301 Double Strand Minimum Bore Type B Roller Chain Sprocket With Hardened Teeth, 3/4 to 1-1/2 in Dia Bore, 3.19 in OD, 35 Chain, 25 Teeth, 3/8 in Pitch, Steel
Browning®Type B minimum bore sprockets are offered in single, double and triple strands. Offerings include 25 to 200 pitch range. Minimum bore sprockets are available in bore ranges from 1/4 to 8-3/8 in.
Selkirk® by Duravent 105240 Single Wall Draft Hood Connector, 5 in Dia x 4-1/2 in L, Steel, Galvanized
Selkirk® by Duravent 105240 Single Wall Draft Hood Connector, 5 in Dia x 4-1/2 in L, Steel, Galvanized
EATON CH270 Type CH Standard Molded Case Circuit Breaker, 120/240 V AC, 70 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
6870-T685-1.2-PG 6870-T685 Astor Bathroom Faucet, 1.2 gpm Flow Rate, 1-9/16 in H Spout, Polished Gold, 2 Handles, Pop-Up Drain
#12 X 1" Bonded Hex Tek-3 Screws
BBI 898204 Wood Screw, #12, 2-1/2 in OAL, Flat Head, Slotted Drive, Zinc CR+3


