Dodge® 117163 Stock Bore Taper Lock Bushing, 1-1/2 in Dia Bore, 2-1/4 in Dia Barrel, 1 in OAL, Sintered Steel
Dodge® Taper-Lock® bushings are flangeless for clean, compact application. They are engineered with an 8 deg taper and a flush-mounted design with no protruding parts providing secure locking and elimination of wobble.
-
BrandDodge®
-
UPC782475494002
-
Manufacturer Part Number117163
-
CountryUSA
-
Taper8 deg
-
MaterialSintered Steel
-
Torque Rating4300 in-lb
-
TypeStock Bore
-
Screw Size3/8 x 5/8 in
-
Number of Bolt Holes2
-
Hub Diameter3-1/4 in
-
Barrel Diameter2-1/4 in
-
Keyway Size3/8 x 3/16 in
-
Bolt Circle Diameter2.13 in
-
Bore Diameter1-1/2 in
-
Overall Length1 in
- Size 1610 bushing
- Clean and compact design
- Easy On/Off operation
- 8 deg taper grips tight, holds tight, runs true and no wobble
- Flush mounting and no protruding parts
-
Alternative Part Number1610 X 1 1/2-KW
-
UNSPSC31171605
-
Package DescriptionEACH
-
Standards/ApprovalsABMA|AGMA|BSA|CEMA|MPTA|PTDA Standards
-
WarrantyLimited
-
Specification Sheet
-
Catalog
-
Instruction/Installation Manual
-
Warranty Information
Recently Viewed
Dodge® 117163 Stock Bore Taper Lock Bushing, 1-1/2 in Dia Bore, 2-1/4 in Dia Barrel, 1 in OAL, Sintered Steel
Dodge® Taper-Lock® bushings are flangeless for clean, compact application. They are engineered with an 8 deg taper and a flush-mounted design with no protruding parts providing secure locking and elimination of wobble.
EATON CH215GFT Type CH Self-Test Ground Fault Circuit Breaker, 120/240 V AC, 15 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
Weiler® 13119 Wheel Brush With Nut, 4 in Dia Brush, 1/2 in W Face, 0.02 in Dia Standard/Twist Knot Filament/Wire, 1/2-13 Arbor Hole
1-1/8" -IDX1-3/8" -OD VITON O-RING
EATON CH250GF Type CH Ground Fault Circuit Breaker, 120/240 V AC, 50 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Quick-make, quick-break switch mechanism combined with inverse time element tripping operation and trip-free handle design. Type CH circuit breakers trip to the off position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off the thermal magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short circuit conditions. Multi-pole breakers have internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
2-15/16" -ID PILLOW BLOCK UNIT-BRWSPB1100EX215/16 >