Main specs
-
-
-
Manufacturer Part Number
218.125P
-
Specification
-
-
-
-
Response Time
20 to 300 ms
-
-
-
-
-
Indicating/Non-Indicating
Non-Indicating
-
-
Body Size
5 mm Dia x 20 mm L
-
Features
-
Designed to international IEC standards for use globally
-
Meets the IEC 60127-2, sheet 3 specification for time lag fuses
-
Used as supplementary protection in appliance or utilization equipment to provide individual protection for components or internal circuits
-
60 min minimum at 150%, 2 min maximum at 210%, 0.2 sec minimum and 10 sec maximum at 275%, 0.04 sec min and 3 sec maximum at 400%, 0.01 sec min and 0.3 sec maximum at 1000% response time
-
Nickel plated brass cap
-
Tin plated copper leads
Additional Information
-
Alternative Part Number
0218.125VXP|9533747
-
-
-
-
Standards/Approvals
UL 248-12|IEC 60127-2|CSA Certified|CE Certified|PROP65: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer
Reviews
There are yet no reviews for this product.
Please log in to write a review.